Study of cyanide treatment in metal plating wastewater of thanh thuy village, thanh oai District, Hanoi City by water hyacinth

  • strict warning: Non-static method view::load() should not be called statically in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/views.module on line 906.
  • strict warning: Declaration of views_handler_argument::init() should be compatible with views_handler::init(&$view, $options) in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/handlers/views_handler_argument.inc on line 744.
  • strict warning: Declaration of views_handler_filter::options_validate() should be compatible with views_handler::options_validate($form, &$form_state) in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/handlers/views_handler_filter.inc on line 607.
  • strict warning: Declaration of views_handler_filter::options_submit() should be compatible with views_handler::options_submit($form, &$form_state) in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/handlers/views_handler_filter.inc on line 607.
  • strict warning: Declaration of views_handler_filter_boolean_operator::value_validate() should be compatible with views_handler_filter::value_validate($form, &$form_state) in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/handlers/views_handler_filter_boolean_operator.inc on line 159.
  • strict warning: Non-static method view::load() should not be called statically in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/views.module on line 906.
  • strict warning: Non-static method view::load() should not be called statically in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/views.module on line 906.
Author: 
Bui Thi Thu, Dao Van Bay, Dang Xuan Thu and Nguyen Thi Hong Hanh
Abstract: 

This paper presents the results of studies on the ability to handle cyanide in metal plating wastewater in the Thanh Thuy village of Thanh Oai district, Hanoi city. The results showed that water hyacinth plants are capable of well growing in the water of pH from 6.00 to 7.00. This plant can be applied for treat cyanide in metal plating wastewater with the concentration about 0.190 mg/L. The water hyacinth with the 2days of age can be applied in treating cyanide with the highest efficiency, reached 89.4 %.

Download PDF: 

CHIEF EDITOR

  

           Prof. Dr. Bilal BİLGİN

Call for Papers - 2017

    submit your paper now

   Vol. 07, Issue 03, March 2017

CURRENT ISSUE

 

Article Tracking

IMPACT FACTOR 2016

          4.753