Development and validation of a stability indicating rp-hplc method for simultaneous determination of haloperidol and benzhexol in pharmaceutical combined dosage forms

  • strict warning: Non-static method view::load() should not be called statically in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/views.module on line 906.
  • strict warning: Declaration of views_handler_argument::init() should be compatible with views_handler::init(&$view, $options) in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/handlers/views_handler_argument.inc on line 744.
  • strict warning: Declaration of views_handler_filter::options_validate() should be compatible with views_handler::options_validate($form, &$form_state) in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/handlers/views_handler_filter.inc on line 607.
  • strict warning: Declaration of views_handler_filter::options_submit() should be compatible with views_handler::options_submit($form, &$form_state) in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/handlers/views_handler_filter.inc on line 607.
  • strict warning: Declaration of views_handler_filter_boolean_operator::value_validate() should be compatible with views_handler_filter::value_validate($form, &$form_state) in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/handlers/views_handler_filter_boolean_operator.inc on line 159.
  • strict warning: Non-static method view::load() should not be called statically in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/views.module on line 906.
  • strict warning: Non-static method view::load() should not be called statically in /home4/vibu/public_html/journalijdr.com/sites/all/modules/views/views.module on line 906.
Author: 
Mathews Bommella, Mukkanti, K. Priyanka, P. and Sarbani Pal
Abstract: 

The study describes development and subsequent validation of a stability indicating reverse-phase HPLC method for simultaneous estimation of the Haloperidol and Benzhexol in combined Pharmaceutical dosage form using RP-HPLC. Separation was accomplished on BDS 250 x 4.6 mm, 5mm C18 column using 0.1% OPA buffer and acetonitrile (45:55 v/v) as mobile phase pumped through at a flow rate of 1 ml/min at 30°C. Optimized wavelength was 210 nm, retention time of Haloperidol and Benzhexol were found to be 2.3 min and 2.7 min respectively. % RSD of the Haloperidol and Benzhexol were found to be 1.1 and 0.8 respectively. Mean recovery were found to be 99.97% and 99.94% for Haloperidol and Benzhexol respectively. The proposed method also proved to be suitable as a rapid and reliable quality control method.

Download PDF: 